3 Mount Elizabeth, Suite #01-02 Medical Centre,
228510, Singapore
Phone Number
+ 65 6733 51888
Email Address
sales@manzoeyecare.com
Visionix VX 120+ Dry Eye
$10,900.00
The Visionix VX 120+ Dry Eye is a multi-diagnostic wavefront anterior segment analyzer, the first to combine Scheimpflug optical pachymetry, Shack-Hartmann wavefront aberrometry, placido ring corneal topography, and an advanced dry eye screening module that can perform a battery of tests to give you a comprehensive analysis of the patient’s visual health.
The Visionix VX 120+ Dry Eye is a multi-diagnostic wavefront anterior segment analyzer, the first to combine Scheimpflug optical pachymetry, Shack-Hartmann wavefront aberrometry, placido ring corneal topography, and an advanced dry eye screening module that can perform a battery of tests to give you a comprehensive analysis of the patient’s visual health.
The VX 120+ Dry Eye is a revolutionary multi-diagnostic instrument that empowers eye care professionals to deliver exceptional patient care. This advanced platform combines several functions into a single, space-saving unit, streamlining your practice and enhancing your diagnostic capabilities.
Comprehensive Eye Health Assessment: Screen for and monitor common eye conditions like glaucoma, cataracts, keratoconus, and dry eye syndrome.
Advanced Dry Eye Analysis: The VX-120+ Dry Eye module provides in-depth analysis of tear film stability, meibomian gland function, and tear meniscus height.
Refractive Assessment and Night Vision Correction: Identify and address vision issues, including those affecting night vision, allowing for customized glasses for optimal visual acuity.
Enhanced Patient Care: Provide a more thorough evaluation and personalized recommendations, fostering trust and patient loyalty.
Increased Practice Efficiency: Automate multiple tests and generate detailed reports, saving you valuable time.
Visionix VX 120+ Benefits
Improved Diagnostic Accuracy: Gain a deeper understanding of your patients’ eye health for informed treatment decisions.
Expanded Service Offerings: Distinguish yourself by offering advanced dry eye analysis and night vision correction capabilities.
Enhanced Patient Satisfaction: Deliver exceptional care and empower patients to make informed choices about their vision.
Increased Profitability: Identify opportunities for premium lenses and contact lens fittings.
Screen and monitor eye pathologies inclusive the dry eye syndrome
Non-Invasive Tear Breakup Time: A test that processes the movement of the rings on the eye and gives the speed of tear film breakup between two blinks.
Meibomian glands: The color camera allows you to make a photo gallery of the parts of the eye and to focus on the meibomian glands area.
Tear Meniscus value: Using the manual zoom of the color camera, you can measure the height of the tear meniscus to complete the test.
Visionix VX 120+ take care of the visual health of all your patients
You will improve your daily practice
You will provide better service and create differentiation
You will have more patients and have the opportunity to sell night glasses
You will receive better trust and an enhanced reputation
Increase quality of service by using a complete diagnostic tool
Distinguish yourself from your competitors and be a recognized vision expert
Reinforce your position as a specialist
Create and/or increase relationships with ophthalmologists
Complete examination of the anterior segment of the eye
Cataracts: Screening and approving candidates for Premium implants
Refractive: Screening and approving candidates for surgery
Glaucoma: Screening and monitoring
Adaptation of rigid and scleral contact lenses
Keratoconus: Screening, stage classification, and monitoring
Identifying refraction needs that are linked to night vision
Also provides complete readings for refraction and keratometry
Screen and monitor Dry Eye Syndrome (DES)
Obtain precise measurements and a visual health assessment of the client
Accurate vision for your patients with customized glasses that may even correct night vision if needed
Create satisfaction and client retention
Reinforce wearer’s feeling of security and trust
Adaptation of premium products
Dimensions
WIDTH: 312 mm (11.28 in.)
DEPTH: 530 mm (20.87 in.)
HEIGHT: 570 mm (22.44 in.)
WEIGHT: 25 kg (55.12 lbs)
VOLTAGE: 100 V – 240 V / 50 Hz – 60 Hz, 300 W
Visionix VX 120+ Genereal Specification
Feature
Value
Alignment
XYZ automatic
Display
10.1” (1 024 x 600) TFT multi-touch screen
Observation area
ø 14 mm
Medical device directive
EC MDD 93/42/EC modified by directive 2007/47/EC
Output
RS232 / USB / VGA / LAN
Power mapping and refraction
Feature
Value
Spherical power range
-20D to +20D
Cylinder power range
0D to + 8D
Axis
0 to 180°
Measuring area
Min. ø 2 mm – Max. 7 mm (3 zones)
Number of measuring points
1,300 points
Acquisition time
0.2 sec
Method
Shack-Hartmann
Pachymetry, IC (iridocorneal) angle and pupillometry
Feature
Value
Method
Continuous horizontal scan with the Scheimpflug camera
Pachymeter measuring range
150-1300 μm
Pachymeter resolution
+/- 10 microns
IC angle measuring range
0°-60°
IC resolution
0.1°
Pupil illumination
Blue light 455 nm
Retroillumination, corneal topography by specular reflection